Upper part V50

Parent Item no. cxmOID589089
  • 5-year warranty
  • KEMA-KEUR, Netherlands
  • Communautés Européennes, EC declaration of conformity according to EC directives
  • EurAsian Conformity
  • Transition from LPZ 0 to LPZ 2
  • Österreichischer Verband für Elektrotechnik, Austria
  • Verband der Elektrotechnik, Elektronik, Informationstechnik e.V., Germany
  • Underwriters Laboratories Inc., USA + CSA, Canada
  • Combination protection device made of type 1
and type 2
  • Installation electrotechnical expertise

Combination arrester, type 1+2

• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)
• Lightning current discharge capacity of 12.5 kA (10/350) per pole
• Modular, plug-in arrestor with dynamic cut-off unit and visual status display
• Locking mechanism with vibration protection and voltage keying
• Plastic (UL 94 V-0)

* Complete = Plug-in arrester and base

All types

All types

Types Highest
continuous
voltage
AC
Pole
version
Protec-
tion
rating
Item no. Quantity SSU
V50-0-320 320 V 1 IP20 5093509
1 piece
Plug-in arrester V50 320 V
Plug-in arrester V50 320 V

Plug-in arrester V50 320 V

Item no. 5093509

Data sheet, 0.17MB, pdf
Download

Connectivity options

SPD to EN 61643-11 Type 1+2
SPD to IEC 61643-11 Class I+II
SPD to UL 1449 Type 4
Nominal voltage AC (50/60 Hz) 230 V
Maximum continuous voltage AC 320 V
Nominal discharge current (8/20 µs) 30 kA
Maximum discharge current (8/20 μs) 50 kA
Lightning surge current (10/350 μs) 12.5 kA
Protection level [L-N] 1.4 kV
Residual voltage [L-N] @ 1 kA 0,9 kV
Residual voltage [L-N] @ 5 kA 1,0 kV
Max. mains-side overcurrent protection 160 A gL/gG
Short-circuit withstand for max. mains-side overcurrent protection 50 kA eff
Operating temperature range -40 - +80 °C
Protection rating IP20
Approvals ÖVE
Connection cross-section, FM terminals 0,5 - 1,5 mm²
Connection cross-section, FM terminals 21 - 16 AWG
Conductor cross-section, flexible (fine-wire) 1.5 - 35 mm²
Conductor cross-section, rigid (single wire/multi-wire) 1.5 - 35 mm²
Conductor cross-section, flexible (fine-wire) 16 - 2 AWG
Conductor cross-section, rigid (single wire/multi-wire) 16 - 2 AWG
TOV voltage [L-N] ‒ fail safe mode ‒ 120 min. 440 V
TOV voltage [L-N] ‒ withstand mode ‒ 5 s 335 V

Dimensions

Size 1 part unit
Minimum distance 1.5 mm
V50-0-385 385 V 1 IP20 5093510
1 piece
Plug-in arrester V50 385 V
Plug-in arrester V50 385 V

Plug-in arrester V50 385 V

Item no. 5093510

Data sheet, 0.17MB, pdf
Download

Connectivity options

SPD to EN 61643-11 Type 1+2
SPD to IEC 61643-11 Class I+II
SPD to UL 1449 Type 4
Nominal voltage AC (50/60 Hz) 350 V
Maximum continuous voltage AC 385 V
Nominal discharge current (8/20 µs) 30 kA
Maximum discharge current (8/20 μs) 50 kA
Lightning surge current (10/350 μs) 12.5 kA
Protection level [L-N] 1.7 kV
Residual voltage [L-N] @ 1 kA 1,1 kV
Residual voltage [L-N] @ 5 kA 1,2 kV
Max. mains-side overcurrent protection 160 A gL/gG
Short-circuit withstand for max. mains-side overcurrent protection 50 kA eff
Operating temperature range -40 - +80 °C
Protection rating IP20
Approvals UL
Connection cross-section, FM terminals 0,5 - 1,5 mm²
Connection cross-section, FM terminals 21 - 16 AWG
Conductor cross-section, flexible (fine-wire) 1.5 - 35 mm²
Conductor cross-section, rigid (single wire/multi-wire) 1.5 - 35 mm²
Conductor cross-section, flexible (fine-wire) 16 - 2 AWG
Conductor cross-section, rigid (single wire/multi-wire) 16 - 2 AWG
TOV voltage [L-N] ‒ fail safe mode ‒ 120 min. 670 V
TOV voltage [L-N] ‒ withstand mode ‒ 5 s 510 V

Dimensions

Size 1 part unit
Minimum distance 1.5 mm
3D data
Invitation to tender text

Invitation to tender text

V50-0-320 / 5093509
Download
V50-0-385 / 5093510
Download
Downloads

Data sheet

V50-0-320 / 5093509, 0.17MB, pdf
Download
V50-0-385 / 5093510, 0.17MB, pdf
Download

Catalogues & Flyers

MCF Compact, V50, V20: The new team to combat surge voltages, 0.80MB, pdf
Download
Lightning protection guide, 25.41MB, pdf
Download

Declarations of conformity